Medical Surgical Masks 1KW Automated BFE Tester 28.3 L/Min 2200cfu

Basic Information
Place of Origin: China
Brand Name: Sujing
Model Number: SJ-X100
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 5 work days
Payment Terms: T/T
Supply Ability: 800/per month
Detail Information
Name: Bacterial Filtration Efficiency Detector Automated Filter Tester Data Storage Capacity: 20G
Data Output And Interface: USB(3) HEPA Performance: ≥99.995%@0.3μm,≥99.9995%@0.12μm
Total Number Of Positive Quality Control Sampler Particles: 2200±500 Cfu Aerosol Generator Mass Median Diameter: Average Particle Diameter (3.0±0.3 µm),geometric Standard Deviation≤1.5
High Light:

2200cfu BFE Tester

,

28.3 L/Min BFE Tester

,

1KW BFE Tester


Product Description

 

Bacterial Filtration Efficiency Detector Automated Filter Tester

 

Bacterial Filtration Efficiency Detector not only conforms to the requirements of medical surgical masks technology YY0469-2011 appendix B in the test method for filter efficiency (BFE) bacteria but also conforms to the American society for testing material ASTMF2100, ASTMF2101, the requirements of the European EN14683 standards, innovative improvements were made on the basis of this, with double pneumatic contrast sampling method at the same time, improve the precision of sampling,It is suitable for measuring and testing departments, scientific research institutes, mask manufacturers and other relevant departments to test the performance of mask bacterial filtration efficiency.

 

Main parameter Range Resolution Accuracy
Anode quality control sampling flow 28.3 L/min 0.1 L/min ±2%
Sampling flow 28.3 L/min 0.1 L/min ±2%
Spray flow 0.1 ~ 10 L/min 0.1 L/min ±5%
Peristaltic pump flow 0.01~3 mL/min 0.01 mL/min ±2%
Operating temperature 0~50 ℃
Biosafety zone negative pressure -90 ~ -120 Pa
Data storage capacity 20G
Data output and interface USB(3)
HEPA performance ≥99.995%@0.3μm,≥99.9995%@0.12μm
Total number of positive quality control sampler particles 2200±500 cfu
Aerosol generator mass median diameter Average particle diameter (3.0±0.3 µm),geometric standard deviation≤1.5
Six-stage Anderson sampler capture particle size classⅠ>7 µm; classⅡ(4.7~7 µm); class Ⅲ(3.3~4.7 µm); class Ⅳ (2.1~3.3 µm); classⅤ(1.1~2.1 µm); class Ⅵ(0.6~1.1 µm)
Aerosol chamber specifications 600 x 80x 3.0mm (Length diameter thickness)
Ventilation flow of negative pressure cabinet >5m3/min
Host size

Working area: 870*600*1100mm

Dimensions:1250*700*2000mm

Working noise < 65db
Working power AC220±10%,50Hz,1KW

 