Name: | Air Quality 24hours Cleanroom Monitoring System For Pharma Factory | Detect Class: | ISO Class 5-9 (EU GMP Grade A-D) |
---|---|---|---|
Standard: | GMP, ISO14644, FDA, JJF1190-2008 | Two Size Channels: | 0.5 & 5.0 Micron Sensitivity |
Flow Rate: | 2.83L/min, Or 28.3L/min | Warranty Time: | 1 Year |
High Light: | REMOTE 3014 Cleanroom Monitoring System,28.3L/Min Cleanroom Monitoring System,Manifold Online Cleanroom Monitoring System |
Manifold Online Particle Counter Cleanroom Monitoring System
At present, Laser particle counter is commonly used in pharmaceutical factories and electronic factories. Some plants are relatively large and require more points. According to a single point, a counter is required, and the cost is relatively large. This system can achieve maximum reduction Cost, and ensure that every point that needs to be monitored can detect data normally. The system has a high degree of automation, simple operation and fast data update.
System composition
Feature of system
REMOTE 3014
2.83LPM (0.1CFM) built-in pump
Outside Dim | 149*118*56 mm³(Wide*Deep*High) |
Weight | 0.8kg |
Max. Consumption | 3.5W |
Power Source | DC24V |
Size Channels | 0.5, 5μm |
Flow Rate | 2.83L/min |
Environmental | Temperature:10℃-40℃; Humidity:20%-90%RH; Atmosphere Pressure:86-106Kpa |
Cycles | Selectable(1s-24h) |
Zero Court | <=10min |
Data Output | RS485(modbus) or 4-20mA |
REMOTE 3104
28.3LPM (1.0CFM) built-in pump
Outside Dim | 275*450*175 mm³(Wide*Deep*High) |
Weight | 4kg |
Max. Consumption | 40W |
Power Source | DC24V |
Size Channels | 0.5, 5μm |
Flow Rate | 28.3L/min |
Environmental | Temperature:10℃-40℃; Humidity:20%-90%RH; Atmosphere Pressure:86-106Kpa |
Cycles | Selectable(1s-24h) |
Zero Court | <=10min |
Data Output | RS485(modbus) or 4-20mA |
REMOTE3102
28.3LPM (1.0CFM)
Outside Dim | 100*45*60 mm³(Wide*Deep*High) |
Power Source | DC9V |
Size Channels | 0.5, 5μm |
Flow Rate | 28.3L/min |
Environment | Temperature:10℃-40℃; Humidity: 20%-90%RH; Atmosphere Pressure:86-106Kpa |
External Vacuum | 60Kpa |
Zero Court | <=10min |
Data Output | RS485(modbus) or 4-20mA |
FKC-III Microbial Air Sampler
Sampling flow rate | 100L/min or 28.3L/min |
Sample volume | 10-9999L |
Sampling delay | 1-60 seconds |
Collection methods | Remote control or manually |
Battery | Lithium Battery 16.8V 8.8Ah, can work 10 hours |
Weight | 6kg |
Plate size | 90*15mm |
Display window | High brightness LCD display |
Operating environment | Temperature: 0 - 50 degree celsius, humidity: 10-90% |